| A basic configuration consists of one DX Cluster Services Node and two DX Storage Nodes |
|
|
| Software |
|
DX Cluster Services Node (DX6000) - DX Content Router Software
|
| DX Storage Node (DX6012S) - DX Object Storage Software3
|
| |
| Software Features |
|
DX Cluster Services Node (DX6000) - Content Routing, Selectable Immutability, Network Services, Replicator Services
|
| DX Storage Node (DX6012S) - Object Storage Management, Storage Optimization
|
| |
| Storage |
|
DX Cluster Services Node (DX6000) - Six 3.5" SATA (7.2K) Hard disk drives
- Available capacities: 250GB2 , 1TB2
|
| DX Storage Node (DX6012S) - Twelve 3.5" SATA (7.2K) Hard disk drives
- Available capacities: 250GB2 , 500GB2 , 1TB2 , 2TB2
|
| |
| Maximum Internal Raw Capacity |
|
| DX Cluster Services Node (DX6000) | DX Storage Node (DX6012S) | |
| Peripheral Bay |
|
| DX Cluster Services Node (DX6000) | DX Storage Node (DX6012S) | |
| Data Protection |
|
DX Cluster Services Node (DX6000) - RAID 5 through PERC H700 (6Gb/s) with 512MB battery-backed cache
|
| DX Storage Node (DX6012S) - User-defined object replication (no RAID required)
|
| |
| Comunication (Standard) |
|
DX Cluster Services Node (DX6000) - Two Dual-Port Broadcom 5716 Gigabit NIC
|
| DX Storage Node (DX6012S) - One Dual-Port Broadcom 5716 Gigabit NIC
|
| |
| Comunication (Optional) |
|
DX Cluster Services Node (DX6000) - Broadcom NetXtreme II 5709C Quad-port GBE Adapter
|
| DX Storage Node (DX6012S) - Broadcom NetXtreme II 5709C Quad-port GBE Adapter
|
| |
| Power |
|
DX Cluster Services Node (DX6000) - Two hot-plug 870W power supplies
|
| DX Storage Node (DX6012S) - 750W non-redundant or redundant hot-plug power supply
|
| |
| Availability Features |
|
DX Cluster Services Node (DX6000) - Hot-plug hard drives, Hot-plug redundant power, Hot-plug redundant cooling, ECC memory, Spare Row Single Device Data Correction (SDDC), iDRAC6 Enterprise or iDRAC6 Express, Tool-less chassis, Cluster support
|
| DX Storage Node (DX6012S) - Hot-swap hard drives, redundant power, ECC memory, Quad-Pack LED
|
| |
| Chassis Dimensions |
|
DX Cluster Services Node (DX6000) - 2U
Height: 8.64cm (3.40") Width: 44.31cm (17.44") Depth: 68.07cm (26.80") Weight (maximum configuration): 26.1kg (57.54lb) |
| DX Storage Node (DX6012S) - 2U
Height: 8.67cm (3.42") Width: 44.52cm (17.53") Depth: 66.46cm (26.17") Weight (maximum configuration): 29.0Kg (63.8lb) |
| |
| System Management |
|
DX Cluster Services Node (DX6000) - Dell OpenManage featuring Dell Management Console
Lifecycle Controller iDRAC6 Enterprise (Optional) VFlash (Optional) |
| DX Storage Node (DX6012S) - BMC, IPMI 2.0 compliant
Lifecycle Controller enabled via iDRAC6 Express (optional) iDRAC6 Enterprise (optional) or VFlash - Unified Server Communicator (optional). |
| |
| Acoustics |
|
DX Cluster Services Node (DX6000) - Idle: LwA-UL4 = 5.5 bels, LpAm5 = 39 dBA
|
| DX Storage Node (DX6012S) - Idle LwA-UL4 = 6.4 bels, LpA5 = 51 dBA
|
| |
| Rail Support |
|
DX Cluster Services Node (DX6000) - ReadyRailsTM sliding rails for 4-post racks, static ReadyRailsTM for 4-post and 2-post racks, and optional support for cable management arm
|
| DX Storage Node (DX6012S) - ReadyRailsTM sliding rails for 4-post racks, static ReadyRailsTM for 4-post and 2-post racks, and optional support for cable management arm
|
| |
| Regulatory and Environmental Compliance |
|
DX Cluster Services Node (DX6000) - Regulatory Model: E02S
Regulatory Type: E02S001 |
| DX Storage Node (DX6012S) - Regulatory Model: E13S
Regulatory Type: E13S001
|
| |